Quadwall Fire Rated Skylights
Fire Rated Roof Assemblies & Roof Covering Materials
Class A, B or C Roof Assembly per the International Building Code (IBC) - ASTM E-108, UL 790, FM 4470
FIRE RATED ROOF ASSEMBLY Test Standards
The specially configured Quadwall® Fire Rated panel system passed all three test standards as required by the IBC and NFPA codes:
- Flame Spread Test
- Intermittent Flame Test
- Burning Brand Test
The following results allowed this system to achieve a Class A Roof Assembly listing:
- No portion of the Quadwall® panels were blown off or fell off the deck in the form of flaming or glowing brands
- The roof deck was not exposed by breaking, sliding, cracking or warping of the glazing panels
- No portion of the Quadwall® panel system fell away in the form of glowing particles
- There was no sustained flaming of the underside of the panel system
Overcome Code Restrictions for Use of Light Transmitting Plastics with A Patented Fire Rated Translucent System
The Quadwall® Fire Rated Roof Assembly has been listed and labeled by Approved Independent Agencies
for Class A, B or C Roof Assemblies & Roof Coverings, as required by the IBC Building Code.
All standard Quadwall systems are rated as Class C Roof Coverings - Specially engineered Quadwall systems are rated as Class A or B Roof Coverings.
CPI Fire Rated Panel Systems provide ALL of the design flexibility and benefits of CPI Daylighting's Quadwall Translucent Panel Systems.